Performance –
The new design will allow for a 2-25 second cycle time across a 20-80 PSI pressure range based on 0.35 – 2.2 GPM flow rates. The MVP factory setting will be set to 8-12 seconds at 60 PSI.
Availability –
The new cartridge design is in production for all current faucets and replacement part sales. Our drinking faucet/bubblers (non-metering) will be in production within the next 30 days.
Interchangeability –
Preserving our tradition of interchangeability this new design offers a seamless transition into past, current and future designs.
Visual Identification –
The metering bushing, pin and spring have been eliminated as illustrated in the graphics below.
Part Numbering –
All replacement part numbers will remain unchanged, such as 670-XJKABNF, 671-XJKABNF, 671-XDAB, 672-XJKABNF and 667-080KJKABNF.